ANNUAL, QUARTERLY ABOVE 11M

Fire door inspections in London

Communal fire doors and flat entrance doors checked for the gaps, seals, hinges and closers that determine whether the door actually holds fire back for as long as it is rated to. Recorded door by door.

Quote required

SPECIMEN RECORD

FD

VALID
REFERENCE
HV-FD-000000
ISSUE DATE
2026-08-21
EXPIRY DATE
2031-08-20
ENGINEER REG.
ENR 000000

PLACEHOLDER RECORD · NUMBERS ILLUSTRATIVE

QUICK ANSWERS

How often do fire doors need checking?

In buildings above 11 metres, communal fire doors quarterly and flat entrance doors annually on a best-endeavours basis. Below 11 metres there is no fixed interval, but your fire risk assessment will usually set one.

What does it cost?

This one is quoted rather than priced online. Ask us for a quote and we will come back with a figure.

What makes a fire door fail?

Most often the gap around the leaf, a damaged or painted-over intumescent seal, or a self-closing device that no longer closes the door onto the latch.

Can you fix problems on the day?

Minor items such as seals and closer adjustment, usually yes. Anything requiring a new leaf or frame is quoted separately.

WHAT IT IS

What an FD actually records.

A fire door is an assembly: leaf, frame, seals, hinges, latch and closer. Change any one of them and the rating no longer holds. The inspection tests the assembly rather than the door.

The record is per door, not per building. A building-level pass tells you nothing about which door on which floor is the one that no longer closes.

LEGAL BASIS

Fire Safety (England) Regulations 2022

Regulation 10 requires responsible persons for multi-occupied residential buildings above 11 metres to undertake quarterly checks of fire doors in common parts and to make best endeavours to check flat entrance doors annually. In all other buildings the duty flows from the fire risk assessment under the Fire Safety Order.

Read the legislationLAST REVIEWED 2026-09
WHO NEEDS THIS

Who this is for, and the properties it applies to.

SUITABLE PROPERTY TYPES

  • Residential property
  • Commercial property

CATEGORY

Fire safety

TYPICAL ATTENDANCE

around 10 minutes per door

WHAT THE INSPECTION COVERS

The inspection, in the order it happens.

Typical attendance: around 10 minutes per door.

  1. Door schedule

    Every door located, numbered and photographed.

  2. Gaps

    The gap around the leaf measured at head, jambs and threshold against the manufacturer's tolerance.

  3. Seals

    Intumescent strips and cold smoke seals checked for damage, paint and continuity.

  4. Hardware

    Hinges, latch engagement, glazing beads and any apertures inspected.

  5. Closer

    The door released from 75mm and from fully open to confirm it closes onto the latch every time.

  6. Record

    Each door passed or failed with photographs and the specific defect, not a building-level summary.

PRICING

This service is quoted, not listed.

Haven has not set a published price for this service yet. Rather than show a figure we cannot stand behind, we will quote it.

Quote required

There is no price on this page and none in the booking flow, because none has been verified. Tell us the property and what you have been asked for, and we will come back with a figure and what it covers.

IF IT DOES NOT PASS

If a door fails

Recorded per door

Each failure is recorded against that individual door with a photograph and the measured defect.

Quick corrections

Seals, closers and hinge adjustment can usually be corrected quickly and cheaply.

Replacement

A damaged leaf, an unsuitable frame or an uncertified door assembly needs replacement, and we quote per door.

Escape routes first

Failures on escape routes are flagged as priority, because a door that does not close is the same as no door at all.

QUESTIONS

Asked about Fire Door Inspection.

It is measured from ground level to the floor surface of the top occupied storey. Roughly five storeys. If you are near the threshold, get it measured rather than estimated.

The door is usually demised to the leaseholder but protects the common escape route, so the responsible person must still make best endeavours to check it. Access refusals should be documented.

Reasonable attempts to gain access, recorded. You are not required to force entry, but you are required to try and to keep evidence that you did.

Yes, as long as the intumescent seal itself has not been painted over or filled. That is one of the most common failures we find.

There is no statutory certificate. What matters is the recorded inspection, the evidence for each door, and that failures were acted on.

ALL 32 BOROUGHS, THE CITY AND INSIDE THE M25

Fire Door Inspection across London.

Haven covers every London borough with one engineer network and one renewal calendar. Where the qualifications overlap, several services can be covered in a single visit.

RELATED

Usually booked in the same visit.

FRA

Fire Risk Assessment

Regulatory Reform (Fire Safety) Order 2005, as amended by the Fire Safety Act 2021 and section 156 of the Building Safety Act 2022

EL

Emergency Lighting Test

Regulatory Reform (Fire Safety) Order 2005, with BS 5266-1

CP12

Gas Safety Certificate

Gas Safety (Installation and Use) Regulations 1998

Ask us about fire door inspection in London.

Tell us the property and what you have been asked for, and we will come back with a price and what it covers.